Direct field documentation from actual Hidalgo County residences and local business facilities. Unedited job diagnostics and installed equipment specifications.
Found on site
Problem
What we did
Solution
Specs
Found on site
Recurring under-slab copper pinhole leaks caused hot water pressure drops and $400 monthly utility spikes.
What we did
Isolated the subterranean manifold, ran overhead PEX-A through the attic chase, installed individual shutoff valves, and restored the drywall openings.
2,400 sq ft · 3.5 Bath · PEX-A manifold
Found on site
The compressor grounded out in a 104°F July week with a full dining room and no day to close.
What we did
Replaced the burnt condenser with a variable-speed inverter system, then rebalanced the ceiling cassettes so the counter and the far tables hold the same temperature.
4 ton · 18 SEER2 inverter · Ceiling cassettes rebalanced
Found on site
The main living space never held temperature: one undersized return could not keep up with a two-storey open plan, and the old registers whistled all evening.
What we did
Added a second return, replaced the trunk takeoffs, set flush ceiling diffusers, and put the ceiling and the floor back the way we found them.
Two-storey open plan · Second return added · Flush diffusers